Installation Instructions

Bulletin 842D DeviceNet MultiĆTurn Absolute Encoders

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Specifications

Electrical

Code Format Natural Binary

Code Direction CW or CCW (programmable)

Electrical Interface DeviceNet specification release 2.0

Operating Voltage 11ć25V DC (24V DC recommended)

Power Consumption 1.8W (75mA @ 24V DC)

Max # of Steps/Revolution 8192

Max # of Revolutions 8192

Position Forming Time 0.3msec

Delay on Power Up 1050msec

Preset Position Via covered rear button or DeviceNet

Mechanical

Angular Acceleration 5 x 10

5

radians/sec

2

Moment of Inertia 35gcm

2

(5.0 x 10

-4

oz-in-sec

2

)

Operating Speed 6000 RPM at max shaft loading

Starting Torque 2.5Ncm (3.5oz-in)

Shaft Loading Axial 11lb (50N)

Radial 67lb (300N)

Environmental

Housing Aluminum

Temperature -20_C to 85_C (-4_F to +185_F)ĊOperating

-40_C to 125_C (-40_F to +257_F)ĊStorage

Humidity 98% noncondensing

Protection NEMA Type 4, 13, IP66 (IEC 529)

Shock 100g/6msec

Vibration 20g/10-2000Hz

Approximate Weight 0.91kg (2lbs)

Selection Guide

Catalog Number

Electrical Connection

842D-60131331BDA

One 5 pin male micro QD

842D-60131331BXA

Two 5 pin micro QDs (one male & one female)

Electrical Connections

As shown in the selection guide, 842D DeviceNet encoders
are available with one 5-pin male micro quick-disconnect or
two 5-pin micro quick-disconnects (one male and one female).
Pin configurations are per the DeviceNet specifications as
follows.

Female Micro

1 Drain

Bare

2 V+

Red

3

4

5

3 V-

Black

2

1

4 CAN_H

White

5CAN_L

Blue

3

4

5

2

1

Male Micro

ATTENTION: Wiring must be in
accordance with the National Electric
Code and applicable local codes and
ordinances.

Manuals and Software

Commissioning the 842D DeviceNet encoder requires an
Electronic Data Sheet (EDS) file be loaded on the system
running the bus management software. Typically, the EDS file
is loaded on a computer running RSNetWorx for DeviceNet.
The EDS file may be downloaded from our website at:
www.ab.com/networks/eds/. Simply select “DeviceNet,”
“RA-Miscellaneous” and press the “Search” button. Select the
842D encoder. This will allow you to download file
00010073002E0400.eds. The User’s Manual may also be
downloaded from our website at:
www.ab.com/manuals/sn/ER.htm.

Saving Parameter Values to EEPROM

Unless parameter values are saved to EEPROM, changes
made to parameter values will not be restored when power is
cycled. In RSNetWorx parameter values are saved to
EEPROM via the Class Instance Editor. Please see the User’s
Manual
for further details.