Installation Instructions

Installation must be in accordance with the following steps and stated specifications and should be
carried out by suitable competent personnel. The unit is not to be used as a mechanical stop. Guard
stops and guides must be fitted. Adherence to the recommended maintenance instructions forms part
of the warranty.

This device is intended to be part of the safety related control system of a machine. Before installation,
a risk assessment should be performed to determine whether the specifications of this device are suit-
able for all foreseeable operational and environmental characteristics of the machine to which it is to
be fitted. Refer to Technical Specifications for Certification information and ratings.

ATTENTION:

The presence of spare actuators compromise the integrity of the safety sys-
tems. Personal injury or death, property damage or economic loss can result.
Appropriate management controls, working procedures and alternative protec-
tive measures should be introduced to control their use and availability.

WARNING:

Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel
could result.

.

Technical Specification

Safety Ratings

CAT4/SIL3

Safety Certifications

TÜV, CE

Safety Standards

IEC60947-5-3, IEC61508, EN954

Certifications cULus
Standards

UL 508

PFHd

1.119 - 10

-9

Operating Characteristics

Sensing Distance (Actuator)

18 mm

30 mm

Assured Make (mm)

15

25

Typical misalignment

(±7 mm in both axes)

Maximum output current (all
outputs, mA)

200

Input Current

50 mA (no load supply current)

Operational Current, Min.

1 mA DC

Off-state Current

< 0.5 mA DC

Maximum # of switches, connected in series

Unlimited. See unit response time section

Operating Voltage

24V DC +10% / -15%
Class 2 SELV power supply

Frequency of operating cycle

1 Hz

Response Time (Off)

54 ms

Case Material

Valox

®

DR 48

Actuator Material

Valox

®

DR 48

Outputs (Guard door closed, Actuator in place)

Outputs

Description

Status

Safety

2 x PNP, 0.2 A max.

ON (+24vdc)

Auxiliary

1 x PNP, 0.2 A max.

OFF (0vdc)

Environmental

Operating Temperature

-10…+55°C (+14…+131°F)

Operating Humidity

5% -95% relative

Washdown rating

NEMA 3, 4X, 12,13, IP 69K

Shock & Vibration

IEC68-2-27 30 g, 11 ms/IEC 68-2-6
10…55Hz

Radio Frequency

IEC 61000-4-3
IEC 61000-4-6

PN-46045 10000054879 Ver 00 October 2009

SensaGuard

TM

18 mm Plastic Barrel Installation Instructions 3