Original instructions, Multiple guardshield safe 2, Mounting brackets – Rockwell Automation 445L GuardShield Safe 2 and Safe 2 PAC Safety Light Curtains User Manual User Manual

Page 12

Advertising
background image

R

GuardShield™ Safe 2 Safety Light Curtain User Manual

10

Original instructions

Figure 8: Determining machine stopping time and safety distance

After installation and alignment of the GuardShield Safe 2 safety light
curtain, the protection field has to be tested with the test rod for the
corresponding resolution (30 mm) according to Figure 9.

Figure 9: Correct testing of the protective field using a test rod

Multiple GuardShield Safe 2

When two or more GuardShield Safe 2s are mounted in close proximity
to one another, it may be possible for the receiver of one GuardShield
Safe 2 pair to receive infrared light from the transmitter of another
GuardShield Safe 2 pair.

There are various techniques to prevent or eliminate the possibility of
optical interference from GuardShield Safe 2 light curtains mounted in
the same plane. The simplest method is to alternate transmitter and
receiver pairs so that the receiver from a second pair is facing away from
the transmitter of another GuardShield Safe 2 pair in close proximity. It
is also possible to place a physical barrier between pairs to prevent the
infrared light from reaching another GuardShield Safe 2 pair.

Figure 10: Multiple GuardShield Safe 2 alignment options

Mounting Brackets

The GuardShield Safe 2 is mounted using brackets which attach to the
side of both transmitter and receiver. It may be necessary to use
additional brackets to mount the GuardShield Safe 2 at a proper safety
distance from the machinery hazard.

Middle of Depth of Protective Field

Safety Distance

Point of Operation

Top of tool

Bottom of tool

To avoid the possibility of
standing between the protective
field and the point of operation,
the distance must be
maintained.

Protective Field Marking

Machine stop
time

T

ransmitter

Rec

eiv

er

Transmitters emit in
opposite direction. Each
receiver receives only the
beams of the appropriate
transmitter.

Transmitters emit in same
direction:
Optical (physical) barrier
necessary

Positioning of the light
curtain: Transmitters emit in
opposite direction.

Advertising