Dimensions - mm (inches) mode of operation, Mounting information, 4sensaguard – Rockwell Automation 440N SensaGuard 18 mm Stainless Steel Barrel Installation Instructions User Manual

Page 4

Advertising
background image

Dimensions - mm (inches)

Mode of Operation

Status indicators:

“Power/Fault” LED illuminates Green -

The unit is ready for operation.

“Power/Fault” LED illuminates Red: -

Door/Guard open. The unit is not ready for operation.

“Power/Fault” LED illuminates flashes Red or Green: -

Unit failure. See Diagnostic section below.

Mounting Information

Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not over torque the
mounting hardware.

Position the switch and actuator so they are aligned with each other.

Mount the switch and actuator to removable guard, door or gate. Keep the switch and actuator within
the sensing range below.

Nut Torque Specification
Barrel Switch: 2.26 N

M (20 in

lbs)

Actuators: 2.26 N

M (20 in

lbs)

Minimum Distance Between Sensors

4

SensaGuard

TM

18 mm Stainless Steel Barrel Installation Instructions

14.43

(0.568)

4.75

(0.187)

16.1

(0.634)

4.57

(0.18) Dia.

2 Places

15.87

(0.625)

13.72
(0.54)

36.47

(1.436)

13.72
(0.54)

15.87

(0.625)

36.47

(1.436)

Actuator

13.9

(0.547)

15.87

(0.625)

74.7

(2.94)

10.4

(0.409)

44.5

(1.75)

16.4

(0.436)

M18 x 1

Sensor

18 mm Actuator

50 mm

Sensor 1

Sens

PA-75056-181, Ver 05 March 2012

Advertising