Fault Config cont.

SCANport Config

Fault Select 2

22

Bit Selection

SP2 Wire Enable

181

Bit Selection

Warning Select 2

23

Bit Selection

SP Enable Mask

124

Bit Selection

Fault Limits

Dir/Ref Mask

125

Bit Selection

Absolute Overspd

24

0.0 rpm/BMS rpm

Start/Jog Mask

126

Bit Selection

Motor Stall Time

25

0.1/3276.7 sec

Clr Flt/Res Mask

127

Bit Selection

Motor Overload %

26

110.0/400.0%

SCANport Status

Line Undervolts

27

10.0/90.0%

Dir/Ref Owner

128

Bit selection

Testpoints

Start/Stop Owner

129

Bit selection

Test Data 1

92

-32768/+32768

Jog1/Jog2

130

Bit selection

Test Select 1

93

0/65535

Ramp/CIFlt Owner

131

Bit selection

Test Data 2

94

-32768/+32767

Flux/Trim Owner

132

Bit selection

Test Select 2

95

0/65535

SCANport Analog

Interface/Comm

SP An In1 Select

133

1/16

Digital Config

SP An In1 Value

134

-32767/+32767

Relay Config

114

0/38

SP An In1 Scale

135

-1.000/+1.000

Relay Config 1

115

-800.0/+800.0%

Sp An In2 Select

136

1/16

Relay Config 2

187

0/36

Sp An In2 Value

137

-32767/+32767

Relay Setpoint 2

188

800.0/+800.0

Sp An In2 Scale

138

-1.000/+1.000

Relay Config 3

189

0/36

Sp An Output

139

-32767/+32767

Relay Setpoint 3

190

-800.0/+800.0

Gateway Data In

Relay Config 4

191

0/36

Data In A1

140

-32767/+32767

Relay Setpoint 4

192

-800/+800.0%

Data In A2

141

-32767/+32767

L Option Mode

116

1/25

Data In B1

142

-32767/+32767

L Option In Sts

117

Bit Selection

Data In B2

143

-32767/+32767

Mop Increment

118

0.0/BMS

Data In C1

144

-32767/+32767

Mop Value

119

0.0/BSMNA

Data In C2

145

-32767/+3276

Pulse In PPR

120

500/2000

Data In D1

146

-32767/+32767

Pulse In Scale

121

0.01/10.00

Data In D2

147

-32767/+32767

Pulse In Offset

122

-BMS/+BMS

Gateway Data Out

Pulse In Value

123

0.0/+8xBMS

Data Out A1

148

-32767/+32767

Analog Inputs

Data Out A2

149

-32767/+32767

An In 1 Value

96

-32767/+32767

Data Out B1

150

-32767/+32767

An In 1 Offset

97

-19.980/+19.980 volts

Data Out B2

151

-32767/+32767

An In 1 Scale

98

-16.000/+16.000

Data Out C1

152

-32767/+32767

An In 1 Filter BW

182

0.0/200.0 rad/sec

Data Out C2

153

-32767/+32767

An In 2 Value

99

-32767/+32767

Data Out D1

154

-32767/+32767

An In 2 Offset

100

-19.980/+19.980 volts

Data Out D2

155

-32767/+32767

An In 2 Scale

101

-16.000/+16.000

An In2 Filter BW

183

0.0/200.0 rad/sec

mA Input Value

102

-32767/+32767

mA In Offset

103

-32.000/+32.000 mA

mA In Scale

104

-16.00

mA In Filter BW

184

0.0/200.0 rad/sec

Analog Outputs
An Out 1 Value +0

105

-32767/+32767

An Out 1 Offset

106

-20.000/+20.000

An Out 1 Scale

107

-1.000/+1.000

An Out 2 Value

108

-32767/+32767

An Out 2 Offset

109

-19.980/+19.980 volts

An Out 2 Scale

110

-1.000/+1.000

mA Out Value

111

-32767/+32767

mA Out Offset

112

-32.000/+32.000 mA

mA Out Scale

113

-1.000/+1.000

Name