Auswahl der Messspanne

SW 2

T

R

R

Poti

1

2

3

4

5

40K

20 Ω

200 Ω

20%

1

1

1

1

1

50K

25 Ω

250 Ω

25%

1

1

1

1

0

60K

30 Ω

300 Ω

30%

1

1

1

0

1

70K

35 Ω

350 Ω

35%

1

1

1

0

0

80K

40 Ω

400 Ω

40%

1

1

0

1

1

90K

45 Ω

450 Ω

45%

1

1

0

1

0

100K

50 Ω

500 Ω

50%

1

1

0

0

1

110K

55 Ω

550 Ω

55%

1

1

0

0

0

120K

60 Ω

600 Ω

60%

1

0

1

1

1

125K

62,5 Ω

625 Ω

62,5%

1

0

1

1

0

130K

65 Ω

650 Ω

65%

1

0

1

0

1

140K

70 Ω

700 Ω

70%

1

0

1

0

0

150K

75 Ω

750 Ω

75%

1

0

0

1

1

160K

80 Ω

800 Ω

80%

1

0

0

1

0

170K

85 Ω

850 Ω

85%

1

0

0

0

1

180K

90 Ω

900 Ω

90%

1

0

0

0

0

190K

95 Ω

950 Ω

95%

0

1

1

1

1

200K

100 Ω

1000 Ω

100%

0

1

1

1

0

250K

125 Ω

1250 Ω

0

1

1

0

1

300K

150 Ω

1500 Ω

0

1

1

0

0

350K

175 Ω

1750 Ω

0

1

0

1

1

400K

200 Ω

2000 Ω

0

1

0

1

0

450K

225 Ω

2250 Ω

0

1

0

0

1

500K

250 Ω

2500 Ω

0

1

0

0

0

550K

275 Ω

2750 Ω

0

0

1

1

1