Rockwell Automation 931S-C3C3J-DC Active Converter User Manual

Page 5

Advertising
background image

Connections
For effective protection from electromagnetic noise, all signal
cables must be shielded, or located on conductive trays or in
conduits.
Strip wires to 7 mm from the ends. Use a suitable ferrule for multi-
stranded wires (do not solder).

Terminal

Signal

1

Supply +

Power Supply

7

Supply −

4

Voltage Input +

Voltage Input

Input Type Jumper to ‘Volts’
Field Supply Jumper to ‘Off’

3

Voltage Input −

2

Current Input +

Current Input

Input Type Jumper to ‘Current’
Field Supply Jumper to ‘Off’

3

Current Input −

3

Device +

Loop Powered Trans-
mitter Input

Input Type Jumper to ‘Current’
Field Supply Jumper to ‘On’

2

Device −

6

Voltage Output +

Voltage Outputs

Output Type jumper to ‘Volts’

5

Voltage Output −

8

Current Output +

Current Outputs

Output Type jumper to ‘Current’

5

Current Output −

Advertising