Rockwell Automation 931H-P2C1D-DC Active Converter, PT100/RTD User Manual

Page 2

Advertising
background image

931H-P2C1D-DC

90

88

97,8

6,1

Type

Order No.

Qty.

Plug-In Jumper
Querverbindung
Connexion transvrsale

Plug-In Jumper, 2-pole, red

1492-CJLJ6-2-R

60

Plug-In Jumper, 3-pole, red

1492-CJLJ6-3-R

60

Plug-In Jumper, 10-pole, red

1492-CJLJ6-10-R 20

Plug-In Jumper, 41-pole, red

1492-CJLJ6-41-R 10

Plug-In Jumper, 2-pole, blue

1492-CJLJ6-2-B

60

Plug-In Jumper, 3-pole, blue

1492-CJLJ6-3-B

60

Plug-In Jumper, 10-pole, blue

1492-CJLJ6-10-B

20

Markers
Verbindermarkierer
Repérage de blocs de jonction

1492-M6X10

200

Power Supply
24 V DC Output

15 W

1606-XLP15E

30 W

1606-XLP30E

50 W

1606-XLP50E

100 W

1606-XLP100E

120 W (5 A)

1606-XLE120E

Accessories / Zubehör / Accessoires

Active Converter, PT100/RTD
931H-P2C1D-DC

Installation Instructions
Beipackinformation
Notice d’utilisation

DIR 10000043420
(Version 00)

10000043420

1. General instructions

• Disconnect power prior to installation
• Installation only by Qualified personnel
• Follow all applicable local and national electrical codes

During range selection, appropriate safety
measures against electrostatic discharge (ESD)
are to be considered.

2. Application

The PT100/RTD Active Converter is designed to galvanically
isolate and convert PT100 signals into standard signals
0(4) ... 20 mA and 0 ... (5)10 V.
The output signal is calibrated switch selectable via
DIP switches (see enclosure).

3. Configuration

Set the DIP switches according to the table printed on
the enclosure (factory setting 0 ... 20 mA).

4. Mounting, electrical connection

The signal conditioners are mounted on standard TS35

rails and fixed in position by a suitable end bracket.

For terminal assignments see enclosure.
Wire cross-section max. 2.5 mm

2

.

ATEX - Approval

Rockwell Automation

UL DEMKO 09 ATEX 147279X 1201South Second Street

T

II 3G Ex nAnL IIC T4

Milwaukee, Wi 53204
U.S.A.

UL Class 1, Division 2 Markings

for selected Signal Conditioners

A.

“This equipment is suitable for use in Class I, Division 2,
Groups A, B, C and D hazardous locations or nonhazar-
dous locations only or the equivalent.”

B.

“WARNING: EXPLOSION HAZARD - Substitution of
components may impair suitability for use in Class I,
Division 2 environments.”

C.

“WARNING: EXPLOSION HAZARD - The area must be
known to be nonhazardous before servicing/replacing
the unit and before installing or removing I/O wiring.”

D.

“WARNING: EXPLOSION HAZARD - Do Not disconnect
equipment unless power has been disconnected and
the area is known to be nonhazardous.”

FOR INSTALLATION IN CLASS I, ZONE 2 LOCATIONS:

E.

This equipment is to be installed into suitable enclosure,
providing a degree of protection not less than IP 54 in
accordance with IEC 60529 unless the apparatus is
intended to be afforded an equivalent degree of protec-
tion by location.

Do not disconnect while circuit is live unless area is known
to be non hazardous. The enclosure for the installation of
the apparatus shall have a protection not less than IP54 in
accordance with IEC 60529

"This device is to be installed in area of a pollution degree
of not more than pollution degree 2, as defined in IEC
60664-1. Alternatively the device may be installed into
enclosure providing a degree of protection not less than
IP 64 in accordance with IEC 60529."

“Connectors are not to be separated when they are
energized.”

T

amb

0 °C to 55 °C

English

PT 100 2-/3-Wire as in EN 60751-1

(2-Wire-Connection by putting

bridge between 2 + 3)

according Part No.

0.8 mA

0...10V / 4...20mA / 0…5V

0...20mA (factory setting)

< 400 Ohm @ power supply ≥ 24 Vdc

> 10 kOhm

< 0.5 % of selected range

< 250 ppm/K of selected range

< 0.7 sec.

24 Vdc (±10%)

approx. 0.6 W

0...+55 °C

-25 °C...+85 °C

88 / 98 / 6.1

100 V

500 V

III

2

6. Technical data*

Input data

Input (fix)

Temperature range

Sensor current

Output data

Output

(selectable)

Load resistance

Output current

Output voltage

Accuracy

Temperature coefficent

Response time

General data

Supply voltage

Power consumption

Operating temperature

Storage temperature

Dimensions L/H/B mm

Coordination of insulation acc. to DIN EN50178, 04/98

Rated voltage

Rated surge voltage

Overvoltage category

Contamination class

* Tu 20 °C

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

10000043420_931H-P2C1D-DC.qxd:10000043420_931H-P2C1D-DC 25.01.2010 11:29 Uhr Seite 2