Rockwell Automation 1329I Integrated AC Drive/Motor, Series B FRN 3.X User Manual
Page 30
Advertising
7-2
Step 7 - Wire the Control Signal Terminal Block
1329I-5.5 Integrated Drive/Motor — January, 2000
Figure 7.1
Control Signal Terminal Block
Table 7.1
Terminal Functions
Terminal Number
Terminal Function
1
10 Volt Reference
2
0 – 10 Volt Speed Reference Input
3
4 – 20 mA Speed Reference Input
4
Common
5
0 – 10 Volt Output
6
Common
7
24 Volt DC
8
Speed Preset 2
9
Speed Preset 1
10
Speed Preset 0
11
Function Loss
12
RPM/Percent Load Display
13
24 Volt DC
14
Forward/Reverse
15
Reset
16
Start
17
Stop
18
24 Volt DC Common
19
N.O. Relay
20
Relay Common
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20