DC (24V) Isolated Output Module

7

Publication 1771ĆIN057B-EN-P - November 2002

Make wiring connections to terminals on the field wiring arm (cat.
no. 1771-WN) shipped with the module.

Attach the wiring arm to the pivot bar on the bottom of the I/O
chassis. The wiring arm pivots upward and connects with the module
so you can install or remove the module without disconnecting the
wires.

1. Make certain all power is removed from the module before

making wiring connections.

2. Swing the wiring arm up into position on the front of the module.

The locking tab on the module will secure it into position.

3. Make connections to the field wiring arm as shown in the

connection diagram below. (Use the label on the front of the
wiring arm to identify your wiring.)

!

ATTENTION

The field wiring arm terminal identification
number is not the same as the number of the bit
which controls that output. You should identify
the labels on the wiring arm with the name or
number of the device connected at each terminal.

Connect Wiring to the

Output Module

Advertising