1791R modules supply expansion power via expansion bus as
follows:
Connect Power to the Module
To apply power to the 1791R module, refer to the illustration below.
Remove the Terminal Block
Follow the directions below to remove the CompactBlock terminal 
block.
1. Unscrew the two retaining screws on the side of the terminal
block.
Expansion power voltage
5Vdc
Expansion power current
100mA
WARNING
!
When you connect or disconnect the Removable 
Terminal Block (RTB) with field side power 
applied, an electrical arc can occur. This could 
cause an explosion in hazardous location 
installations.
Be sure that power is removed or the area is 
nonhazardous before proceeding.
Pin Number
Name
1
Com (24V dc return)
2
Gnd (Field ground)
3
+24V dc
Module power 
connector
43108
COM
GND
+24V