Output Override and I/O Update Instructions
Chapter 7
7Ć17
Table 7.C
Average Execution Times in Microseconds for FILEĆTOĆFILE AND, OR,
XOR Instructions when Instruction is True
Rate Per Scan
Dist. Complete Mode
Complete Mode
ăă5
ă10
ă15
ă25
ă50
100
256
512
ă174
ă223
ă272
ă370
ă615
1105
2648
5171
ă148
ă197
ă246
ă344
ă589
1079
2622
5145
Formula for more exact approximations can be found in Section C.6.
Execution Time for incremental mode is 100 microseconds per scan.
When FALSE, execution time is 17.6 microseconds.
Table 7.D
The Following Instructions Reset the Watchdog Timer
FileĆToĆFile Move
WordĆToĆFile Move
FileĆToĆWord Move
FileĆToĆFile AND, OR, XOR
WordĆToĆFile AND, OR, XOR
File Complement
File Search
File Diagnostic
Return
End
T.End
SBR
Sequencer In
Sequencer Out
Sequencer Load
Fifo Load
Fifo Unload
Shift File Up
Shift File Down
Shift Bit Left
Shift Bit Right
Block Transfer (for processors equipped with cat. no. 1772ĆLG, processor module, Rev. J firmware
or later)