Specification

1769-OW16

Voltage Category

AC/DC normally open relay

Operating Voltage Range

5 to 265V ac
5 to 125V dc

Number of Outputs

16

Bus Current Draw (max.)

205 mA at 5V dc line
180 mA at 24V dc line

Heat Dissipation

4.75 Total Watts
(The Watts per point, plus the minimum Watts, with all points
energized.)

Signal Delay (max.) – resistive load

turn-on = 10 ms
turn-off = 10 ms

Off-State Leakage (max.)

0 mA

On-State Current (min.)

10 mA at 5V dc

Continuous Current per Point (max.)

2.5A (Also see "Relay Contact Ratings" on page 16.)

Continuous Current per Common (max.)

10A

Continuous Current per Module (max.)

20A

Power Supply Distance Rating

8 (The module may not be more than 8 modules away from the
power supply.)

Output Point to Bus Isolation

Verified by one of the following dielectric tests: 1836V ac for 1
sec. or 2596V dc for 2 sec.
265V ac working voltage (IEC Class 2 reinforced insulation)

Isolated Groups

Group 1: outputs 0 to 7
Group 2: outputs 8 to 15

Output Group to Output Group Isolation

Verified by one of the following dielectric tests: 1836V ac for
2 sec. or 2596V dc for 2 sec.
265V ac working voltage (basic insulation)
150V ac working voltage (IEC Class 2 reinforced insulation)

Vendor I.D. Code

1

Product Type Code

7

Product Code

85