The following information applies when 
operating this equipment in hazardous 
locations:
Informations sur l’utilisation de cet équipement 
en environnements dangereux :
Products marked “CL I, DIV 2, GP A, B, C, D” are 
suitable for use in Class I Division 2 Groups A, B, C, 
D, Hazardous Locations and nonhazardous locations 
only. Each product is supplied with markings on the 
rating nameplate indicating the hazardous location 
temperature code. When combining products within 
a system, the most adverse temperature code (lowest 
“T” number) may be used to help determine the 
overall temperature code of the system. 
Combinations of equipment in your system are 
subject to investigation by the local Authority Having 
Jurisdiction at the time of installation.
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne 
conviennent qu’à une utilisation en environnements 
de Classe I Division 2 Groupes A, B, C, D dangereux 
et non dangereux. Chaque produit est livré avec des 
marquages sur sa plaque d’identification qui 
indiquent le code de température pour les 
environnements dangereux. Lorsque plusieurs 
produits sont combinés dans un système, le code de 
température le plus défavorable (code de 
température le plus faible) peut être utilisé pour 
déterminer le code de température global du 
système. Les combinaisons d’équipements dans le 
système sont sujettes à inspection par les autorités 
locales qualifiées au moment de l’installation.
WARNING
!
EXPLOSION HAZARD
•
Do not disconnect 
equipment unless 
power has been 
removed or the area is 
known to be 
nonhazardous. 
•
Do not disconnect 
connections to this 
equipment unless 
power has been 
removed or the area is 
known to be 
nonhazardous. Secure 
any external 
connections that mate 
to this equipment by 
using screws, sliding 
latches, threaded 
connectors, or other 
means provided with 
this product.
•
Substitution of 
components may impair 
suitability for Class I, 
Division 2.
•
If this product contains 
batteries, they must 
only be changed in an 
area known to be 
nonhazardous.
AVERTISSEMENT
!
RISQUE D’EXPLOSION
•
Couper le courant ou 
s’assurer que 
l’environnement est 
classé non dangereux 
avant de débrancher 
l'équipement.
•
Couper le courant ou 
s'assurer que 
l’environnement est 
classé non dangereux 
avant de débrancher les 
connecteurs. Fixer tous 
les connecteurs 
externes reliés à cet 
équipement à l'aide de 
vis, loquets coulissants, 
connecteurs filetés ou 
autres moyens fournis 
avec ce produit.
•
La substitution de 
composants peut rendre 
cet équipement 
inadapté à une 
utilisation en 
environnement de 
Classe I, Division 2.
•
S’assurer que 
l’environnement est 
classé non dangereux 
avant de changer les 
piles.