Programming chapter 3 – Rockwell Automation 1772-AF4,D17726.5.3 User Manual, AUX FUNCT PROM User Manual

Page 21

Advertising
background image

Programming

Chapter 3

3Ć13

4.

Enter values for operands 1 and 2.

You can enter these values from the keyboard of your industrial terminal or
through ladder diagram functions. Entry of operand 1 - 102746 and operand 2 -
256384 produces the result 359130 when the addition function executes.
Figure 3.4 shows how the result is stored.

Figure 3.4

AF4 Addition Function Format After Execution

17 16 15 14 13 12 11 10 7 6 5 4 3 2 1 0

S

0

2

Bit No

Data Address

Operand 1

Operand 2

S

Result Address

Result

D ER

E

E = Enable Bit (1 = Function in Progress)

S = Sign Bit (1= Negative)

D = Done Bit (1 = Function Complete)

ER = Error Bit (1 = Overflow)

11483

Word 201

Word 202

Word 203

Word 204

Word 305

Word 306

(0)

S

(0)

1

4

6

7

5

6

2

8

4

3

5

9

3

3

0

1

(0) (0) (1) (0)

Entry and Display of Input and Result Values

Figure 3.5 shows one method for inserting input values and displaying input
values and results of AF4 addition computations. Although there are several
techniques for accomplishing this, we chose get instructions. The first rung
requests an AF4 addition. The second rung shows the two operands in its top
branch and the resultant sum in its lower branch.