Technical data – Rockwell Automation 1785-TR10B2 Coax Transceiver for 10BASE2 Installation Instructions User Manual

Page 7

Advertising
background image

1785-5.18 - January 1999

Coax Transceiver for 10BASE2

7

Technical Data

Operating voltage

+12 V

Current consumption (no signal) 2

50 mA

Bit rate (Manchester Code)

10 Mbit/s

Coaxial cable interface: Transmitter

AC
DC
Rise/fall time
Harmonic components:
1st harmonic
2nd harmonic
3rd harmonic
4th harmonic
5th harmonic
6th harmonic
7th harmonic and higher

1.9 V +0.35 V, –0.5 V
–1.025 V ±0.1 V
25 ns ±20%

–34 dB
–23 dB
–40 dB
–39 dB
–40 dB
–47 dB
–55 dB

Preamble loss transmit

2 bit

Stady State Delay

15 ns

Jabber protect time out

25 ms

Jabber reset

500 ms

Coaxial cable interface: Receiver

Coaxial cable Input current

5 µA

Capacitive load

2 pF

Input resistance

> 100 k

Noise suppression

–250 mV

Preamble loss receive

1 bit (max. 3 bit)

Steady State Delay

10 ns

Collision Detect threshold

–1.6 V

Transceiver interface (AUI)

Input:
Terminating resistance
Sensitivity
Maximum DC component


78

±1%

500 mVPP
± 50 V

Output:
Output voltage
(data and CD signal)
CD signal frequency
SQE Test (heart beat)

delay time
length

AUI cable length



1.6 VPP
10 MHz ± 10%
can be disabled
1100 ns
1000 ns
0 to 50 m max.

Connections with pin assignments
Transceiver interface
(15-pin sub-D plug)



Coaxial cable interface


Input:

DO-A: Pin 3; DO-B: Pin 10

Output:

DI-A: Pin 5; DI-B: Pin 12

Collision detect:CI-A: Pin 2; CI-B: Pin 9
Power:

GND: Pin 6; +12 V: Pin 13

Shielding:

Pin 1, 4, 8, 11, 14

1 BNC socket

Advertising