18 Remote I/O Adapter Module

Publication 1747-IN014C-EN-P - January 2003

Specifications

Adapter Operating Specifications

Baud Rate Determination of Maximum Cable Length and Terminating
Resistor Size

Backplane Current Consumption

375 mA at 5V dc

Operating Temperature

32°F to 140°F
(0°C to 60°C)

Storage Temperature

-40°F to +185°F
(-40°C to +85°C)

Humidity

5% to 95% non-condensing

Noise Immunity

NEMA standard ICS 2-230

Vibration

Displacement: 0.015 inch, peak-to-peak at 5-57 Hz

Acceleration: 2.5Gs at 57-2000 Hz

Shock (operating)

30Gs

Agency Certification
(when product or packaging is marked)

UL Listed

CSA certified

Class I, Division 2 Groups A, B, C, D

CE compliant for all applicable directives

Marine Certified

C-tick marked for all applicable acts

Baud Rate

Maximum Cable Distance
(Belden 9463)

Resistor Size

Using Extended
Node Capability

57.6K baud

3048 meters (10,000 feet)

82

1/2 Watt

115.2K baud

1524 meters (5,000 feet)

230.4K baud

762 meters (2,500 feet)

Not Using
Extended Node
Capability

57.6K baud

3048 meters (10,000 feet)

150

1/2 Watt

115.2K baud

1524 meters (5,000 feet)

230.4K baud

762 meters (2,500 feet)