Estimate maximum input scan time, Estimate minimum output scan time – Rockwell Automation 1747-PCIS2 PCI Bus Card User Manual

Page 10

Advertising
background image

10

PCI Bus Card for 1746 Local I/O

Publication 1747-5.31–April 1998

Estimate Maximum Input Scan Time

Estimate Minimum Output Scan Time

Quantity

Fixed Scan
Time

Total

Minimum Input Scan Time
(from previous table)

Maximum Specialty I/O Input Scan Time
number of class 1 specialty I/O modules:
number of class 3 and 4 specialty I/O modules:

X 50 =
X 200 =

Maximum Input Scan Time (total)

Quantity

Fixed Scan
Time

Total

Digital I/O Modules:
number of class 0 input words:

X 46 =

Specialty I/O Modules (Class 1)
number of 1746-BAS modules (class 1):
number of 1746-NIO4V modules:
number of 1746-FIO4V modules:
number of 1746-NO4V modules:

X 500 =
X 277 =
X 277 =
X 330 =

Specialty I/O Modules (Class 3 and 4)
number of 1746-HSCE modules:
number of 1747-SN modules:
number of 1746-BAS modules (class 4):

X 608 =
X 1208 =
X 655 =

Forced Output Overhead
number of class 0 output words:
number of specialty output words:
number of specialty I/O modules:

X 6 =
X 9=
X 30 =

Output Scan Overhead (Add this time to the total from the I/O modules)

36

Minimum Input Scan Time (total)

Advertising
This manual is related to the following products: