12 ControlNet Adapter Module
Publication 1747-IN017C-EN-P - May 2001
Connecting Programming Terminals to the Network via the NAP
You can connect programming terminals to the ControlNet network by connecting 
to the network access port (NAP). Two methods are shown below.
ATTENTION
!
Use the 1786-CP cable when connecting a programming 
terminal to the network through NAPs. Using a commercially 
available RJ-style cable could result in possible network 
failures.
Using 1784-KTC or -KTCx communication card 
and NAP
Programming 
Terminal
1784-KTC or 
-KTCx
1786-CP
1
ControlNet 
product
ControlNet network
Using 1770-KFC communication 
interface and NAP
Programming 
Terminal
Serial or Parallel 
Connection
ControlNet Network
1. The 1786-CP cable can be plugged into any ControlNet product’s NAP to provide programming capability on the
ControlNet network. A programming terminal connected through this cable is counted as a node and must have a 
unique address.
1786-CP
1
1770-KFC
ControlNet 
product