Rockwell Automation ControlFLASH Firmware Upgrade Kit User Manual User Manual
Page 42
 
42
Rockwell Automation Publication 1756-UM105E-EN-E - October 2012
Appendix A ControlFLASH Software Error Codes
Out of Memory Error Log File Error
The log file could not be accessed because of a file error. Either the log file 
could not be:
• Opened.
• Written to because of an error.
• Written to because the disk is full.
ATTENTION: Check with your application engineer or supervisor before 
deleting any files. Verify that you are not deleting any files necessary for 
system operation.
 If the disk is full, you can free up disk space by:
• Deleting files from your c:\windows\temp directory.
• Uninstalling any unnecessary applications.
• Shutting down and restarting your computer.
Authenticate Error
The download restrictions placed on the selected revision could not be 
validated. Files containing validation information are corrupted or have been 
deleted. Check with a technical support representative for help in restoring 
your restriction files.
Restriction System Error
The download restriction system could not read the master key disk. Check 
with a technical support representative for help in resolving this problem.
RSLinx Load Error
An error occurred while the ControlFLASH software tried to install the 
network protocol driver (DTL32.DLL). Verify that RSLinx Classic software is 
properly installed and configured.
Communication Error
An error occurred while the ControlFLASH software tried to communicate 
with the target device.
Verify that:
• All cable connections are secure.
• The target device has power.
• RSLinx Classic software is properly configured.
Mode Error
The target device is in a mode in which it cannot be programmed. Place the 
device into the appropriate mode.
Failed to communicate to the target 
device. You do not have the permission 
to perform this operation.
The error might be caused because that:
• The security authority identifier of the target device does not match the 
identifier in FactoryTalk Services Platform. Make sure you have the 
permission to perform the operation.
• The slot used for the controller is not a trusted slot. Make sure to use a
trusted slot for the controller.
Error Message
Description