Ultra5000 I/O Pinouts

The tables are arranged to match the drive’s I/O pin arrangement.
Refer to the Ultra5000 Hardware Installation Manual
(2098-IN001x-EN-P) for more information on these signals.

Related Documentation

Documents cited contain additional information concerning related
Allen-Bradley products or general information that may be helpful. To
obtain a copy, contact your local Rockwell Automation office or
distributor, or access the documents on-line at
www.theautomationbookstore.com or
www.ab.com/manuals/gmc.

CN1A Connector

CN1B Connector

Pin

Signal

Pin

Signal

Pin

Signal

Pin

Signal

15

INPUT9

1

INPUT1

2

8

+5VCOM

1

+5V

16

INPUT10

2

INPUT2

2

9

AIN1

2

AX+

17

INPUT11

3

INPUT3

10

AIN2

3

AX-

18

INPUT12

4

INPUT4

11

+5VCOM

4

BX+

19

INPUT13

5

INPUT5

12

AOUT1

5

BX-

20

INPUT14

6

INPUT6

13

AOUT2

6

IX+

21

INPUT15

7

INPUT7

14

SHIELD

7

IX-

22

INPUT16

8

INPUT8

23

OUTPUT5

9

OUTPUT1

24

OUTPUT6

10

OUTPUT2

25

OUTPUT7

11

OUTPUT3

26

OUTPUT8+

12

OUTPUT4

27

OUTPUT8-

13

SHIELD

28

IOCOM

1

14

IOPWR

1

1

The Ultra5000 0.5, 1.0, and 2.0 kW, and all 460V drives (2098-IPD-005-xx, 2098-IPD-010-xx, 2098-IPD-020-xx, and

2098-IPD-HVxxx-xx models) require a user supplied I/O power source.