Rockwell Automation 2755 Decoded Hand-Held Scanner User Manual
Page 130

E–2
AdaptaScan Pass Through Application
Publication 2755-6.5
The custom cable for the AdaptaScan Pass Through cable connects to the
RS-232 and package detect terminals in the AdaptaScan wiring base.
Transmit (Tx)
No Connection
Receive (Rx)
Clear to Send (CTS)
Ready to Send (RTS)
Shield (SHD)
Custom Cable
Maximum length of
18 inches (.46 meter)
AdaptaScan Wiring Base
PKG DET
+12VDC
Ground
25-Pin
Female DB Connector
No Connection
No Connection
The following table provides the pinout connections for the cable (DB
25-pin female connector).
Pass Through Cable
Pin Number
Function
AdaptaScan Terminal Connection
2
Receive Data Input
Tx (RS-232 Terminal Block)
3
Transmit Data Output
Rx (RS-232 Terminal Block)
4
CTS Input
RTS (RS–232 Terminal Block)
5
RTS Output
CTS (RS-232 Terminal Block)
7
Ground
GND (Package Detect Terminal Block)
9
+V 4.8 to 14.0V DC
12V (Package Detect Terminal Block)
Shield
Shield Ground
SHD (RS-232 Terminal Block)