Display Panel & Fault Diagnostics
Chapter 10
10-109
I/O Outputs
This parameter indicates the status of all outputs. For ease in identifying
each output, successive letters of the alphabet are used to show when they
are On. When an output is Off, a dash (–) will be displayed. Refer to
Table 10.B for the output associated with each letter.
Data Format (line 1): I/O Outputs
Data Format (line 2): I/O ABCDEFGHI
Table 10.B
I/O Outputs
Display Letter
Output Signal Name
A
Zero Speed
B
At-Speed
C
Speed Level Indicator
D
Load Level Indicator
E
No Hard Fault
F
No Soft Fault
G
Drive Ready
H
In-Position
I
High Motor Winding Selected
Current Fault
Indicates the current fault diagnostic message. The message uses 13
characters on line 2 of the display.
Fault History
Indicates a fault diagnostic message from the fault history queue. The 8
most recent messages are retained with #1 being the newest message. The
message can use the last six characters on line 1 and 13 characters on line 2
of the display.
The Scroll+ and Scroll- keys are used to scroll through the message queue.