Wiring
Chapter 8
8-90
Figure 8.9
Orient Feedback Wiring
CN2-1
FG1
CN2-19
AA
CN2-13
AA Return
CN2-18
CN2-12
AB
AB Return
CN2-17
CN2-11
AZ
AZ Return
CN2-5
+12V DC
CN2-3
GND
Mag
Sensor
CN2-1
FG1
CN2-16
DA
CN2-10
GND
CN2-15
CN2-9
DB
GND
CN2-14
CN2-8
DZ
GND
CN2-5
+12V DC
CN2-4
GND
845T
Encoder
845T Wiring
High Resolution Magnetic Sensor Wiring
Dual Winding Motor Contactor Control Wiring
When a dual winding 1327AD series motor is used with the 8510, the user
must supply two power contactors that will be used to switch the motor
between the
∆
and Y winding configurations. In addition, a 24V DC power
source must be supplied to operate the contactors. Refer to Table 7.A for
the specific contactors that are required for each drive size. The drive will
control the operation of these contactors through the 20 pin CN1 connector
(see Figure 7.3 for location).
The interface cable for this function requires four twisted pairs. The
recommended cable is:
Madison #08CFJ00004 (4 twisted pairs with shield, #24 AWG)
Three termination options are available for the CNl connector: l) a mating
connector kit, 2) a termination panel, and 3) an interface cable assembly.
The following table shows the I/O function assignment for each of these
termination options.