4 Standard Feedback Cables with SpeedTec DIN Connector Type 623

Publication 2090-IN029A-EN-P - September 2010

Install Cables

Follow these steps when installing a cable.

1.

Identify the recommended installation areas and the correct offset from features before
beginning any cable bend. Features include these areas on the cable:

Connectors

Transitions from exposed wire to insulation (for example, flying leads)

Exposed cable ground shields

The offset from these features should be greater than or equal to (>1x) the cable
diameter.

2.

Keep cable bends within the bend radius specified on

page 7

.

3.

When installing the cable observe these restrictions:

The bend zone is the area in which the cable can bent to its specified bend radius.

The installation areas require strain relief to minimize cable flexing, and to reduce
the possibility of cable fatigue where the cable connects to other components.

4.

Identify each connection on a cable by attaching a label around the outer insulation of
each wire adjacent to the drive connection.

Limited Bend Zone

Flex Restrictions Apply

2090-CFBM7E7-CDAFxx shown

Installation Area

300 mm (12 in.) approx.

Bend Radius
Refer to

Specifications

for value.

Installation Area

300 mm (12 in.) approx.

Advertising