Epi str-link data recorders – Rockwell Automation 2706 DL20 SERIES G USER MANUAL User Manual
Page 136

Appendix B
Tape Recorder Setup
B–10
The EPI STR-LINK Recorders can be used as as storage device for DL20
messages. There are DIP switches inside the STR-LINK II and III which
configure its operation. Refer to the user manual for the data recorder to
access DIP switches. The DIP switches must be set as follows:
STR-LINK II Switch Settings
I/O Board DIP Switch
Switch 1 Open
Switch 2 Open
Switch 3 Open
Switch 4 Closed
Tape Interface Board DIP Switch
Switch 1 Open
Switch 2 Closed
Switch 3 Open
Switch 4 Open
Switch 5 Open
Switch 6 Closed
Switch 7 Closed
The front panel switches must be set as follows:
Baud Rate
1200
I/O Select
RS-232
Stop Bits
1
Mode Select
Full Duplex
STR-LINK III Switch Settings
10 Position DIP Switch
Switch 1 Left
Switch 2 Left
Switch 3 Left
Switch 4 Right
Switch 5 Left
Switch 6 Right
Switch 7 Right
Switch 8 Right
Switch 9 Left
Switch 10 Right
The front panel switches must be set as follows:
Track Select
Both
Baud Rate
1200
EPI STR-LINK
Data Recorders