Mount the power rail – Rockwell Automation 2093-PRSxx Kinetix 2000 Power Rail Installation Instructions User Manual

Page 4

Advertising
background image

4 Kinetix 2000 Power Rail

Publication 2093-IN004A-EN-P - December 2006

Kinetix 2000 Power Rail Dimensions

Mount the Power Rail

The Kinetix 2000 power rail comes in several lengths. Power rails will support one integrated
axis module, additional axis modules, and a shunt module (catalog numbers 2093-AC05-MPx,
2093-AMPx, 2093-AM0x, and 2093-ASP06). Additional open slots must have a slot filler
module (2093-PRF) installed to provide continuity for control signals and system power.

Follow these steps to mount a Kinetix 2000 power rail.

1. Lay out the position for your power rail in the enclosure.

For panel layout recommendations, refer to the Kinetix 2000 Multi-axis Servo Drive
User Manual,
publication 2093-UM001. Mounting hole dimensions are provided in
the figure and table.

2. Attach the power rail to the cabinet.

The recommended mounting hardware is M4 metric bolts.

Catalog
Number

Power Rail
Axis

Dimension, Approx.

A

mm


(in.)

B

mm


(in.)

C

mm


(in.)

2093-PRS1 1

90.0

(3.54)

N/A

N/A

2093-PRS2 2

130.0

(5.12)

40.0 (1.58)

N/A

2093-PRS3 3

170.0

(6.69)

80.0 (3.15)

N/A

2093-PRS4 4

210.0 (8.27) 120.0 (4.72) N/A

2093-PRS5 5

250.0 (9.84) 160.0 (6.30) N/A

2093-PRS7 7

330.0 (12.99) 240.0 (9.45) 120.0 (4.72)

2093-PRS8S 8

410.0 (16.14) 320.0 (12,60) 160.0 (6.30)

ATTENTION

These procedures assume you have prepared your panel and understand
how to bond your system.

Refer to the Kinetix 2000 Multi-axis Servo Drive User Manual,
publication 2093-UM001, for detailed instructions on how to ground and
bond your power rail.

Advertising