Remote Keyswitch and RS-232 Assembly

Installation Data

3

Figure 3
Cutout Dimensions

CL

CL

20159a

2.625”

(66.7 mm)

2.625”

(66.7 mm)

3/16”

4 Places

3.000”

+0.025”
–0.000

76.2 mm

+0.025”
–0.000

(

)

2. Install the assembly in the cutout, from the rear of the panel.

3. Use the washers provided between the screw heads and the front side of

the panel. The narrow end of the washer is oriented towards the head of
the screw, as illustrated in Figure 1.

4. Fasten the housing to the panel door with the four mounting screws

provided. To maintain a good seal, torque the screws down to between 9
and 12 inch-pounds.

5. Before installing the lower left mounting screw, thread the screw

through the end of the restraining chain attached to the cap. Then install
the screw in the housing.

6. Connect the RS-232 connector on the assembly to the RS-232 serial

interface port on the rear of the PanelView terminal (Figure 4). Attach it
with the mounting screws on the connector housing.

Figure 4
RS-232 Serial Interface Port on the Back of the Terminal

23745

CONFIGURE

RUN

RUN

CONFIGURE

RS–232 Serial Interface

RS-232 Serial Interface

Mode Select Keyswitch