Rockwell Automation 9000 UL325 Recognized Sensors User Manual

Installation instructions photoswitch, Ul325 recognized photoelectric sensors

Advertising
background image

Installation Instructions

PHOTOSWITCH

R

UL325 Recognized Photoelectric Sensors

M

odels

Sensors

10- 55V DC/20- 40V AC Models

70- 264V AC/DC Models

2m 300V cable

60--2728

60--2730

5-pin mini QD

60--2729

60--2731

O

pti

cal

Sensing Mode

Retroreflective

Sensing Distance

2.54cm to 9.15m (1I to 30i) with AB#92--39 reflector

Transmitting LED

Visible Red, 660nm

Field of View

1.5_

Operating Mode

Light/dark operate selectable

Sensitivity Adjustment

Yes

Elec

tric

al

Operating Voltage

10--55V DC/20--40V AC

70--264V AC/DC

Supply Current

40mA max

15mA max

Power Consumption

2.2W / 1.6VA

Protection

False pulse on power-up, overvoltage, reverse polarity, outputs short circuit (SCP) protected

Output Type

SPDT EM Relay

Output Load Current/Voltage

1A @ 264V AC, 2A @ 132V AC

Response Time

15ms

Leakage Current

Not applicable

Me

ch

an

ic

al

Housing/Lens Material

Valoxt/Acrylic

LED Indicators

See table below

Connection Types

SJTOW outdoor rated 2m, 300V cable, 5-pin AC mini QD

Supplied Accessories

AB #60--2725 impact bracket

Optional Accessories

#92--39 reflector, 889N--F5AF--6F cordset

Env

ironment

al

Operating Temperature

--34_C to +70_C (--29_F to +158_F)

Relative Humidity

5–95%

Operating Environment

NEMA 3, 4, 4X, 6P, 13, IP67 (IEC529); 1200psi (8270kPa) washdown

Approvals

c--UL recognized (UL325), CE marked for all applicable directives

Protections

All versions: false pulse, reverse polarity, overload, short-circuit

Vibration

10--55 Hz, 1mm amplitude, meets or exceeds IEC 60947--5--2

Shock

30G with 1ms pulse duration, meets or exceeds IEC 60947--5--2

Wiring Diagrams

5-pin AC/DC Mini QD Model: 60--2729, 60--2731

Cable Model: 60--2728, 60--2730

Brown

Orange (C)

Black (NO)

Blue

White (NC)

4 Brown

3 Orange (C)

1 Black (NO)

2 Blue

5 White (NC)

( + ) L1

( -- ) L2

1

3

2

4 5

( + ) L1

( -- ) L2

Note

: Quick-disconnect wiring codes shown are valid for Allen-Bradley cables only.