2 Single Motor Cables with Circular DIN Connector Type 740

Rockwell Automation Publication 2090-IN049A-EN-P - October 2013

Follow these guidelines when installing a single motor cable:

Do not bend the cable within 76.2 mm (3.0 in.) of the connector or the flying-lead end.
See the

Installation Guidelines

illustration.

Do not exceed the bend radius limitation specified in the

Specifications on page 3

.

Refer to

Cable Pinouts and Schematics on page 3

to identify each wire and its respective

drive connection.

Remove and discard the protective sleeve from the data signal wires shortly before you
install these wires on the feedback connector kit.

Connect unused brake conductors to the drive to prevent accidental contact.

For continuous-flex cables, follow these additional installation requirements:

The continuous-flex zone is the area where the cable can repeatedly flex up to its
specified bend radius.

Installation areas require rigid mounting to prevent the cable from flexing where it
connects to other components.

Installation Guidelines

Continuous-flex Zone

Installation

Area

Installation

Area

Signal

Labels

Exposed Shield

Shrink
Wrap

Refer to

Specifications on page 3

for recommended

continuous-flex zone radius values.

Insulated and
Shielded
Twisted Pair

2090-CSBM1DF-10AF

xx cable shown.

76.2 mm

(3.0 in.)

76.2 mm

(3.0 in.)

Bend
Radius

Bend Radius