Armature SCR Replacement (for 3000A 1395 Drives)
Replacing the SCRs
1.
Connect the armature-pulse transformer board connectors to the 
SCR leads (SD3100 drives will need to have pulse-gate amplifier 
board connectors crimped onto the SCR leads).
2.
Apply silicone oil to the contact surfaces of the SCR.
3.
Place the SCR, orienting it properly, and fit the roll pins into the 
SCR indentations (take care not to damage the SCR). The gate 
leads should extend out the right side (see the leads illustrated in 
Figure 1).
4.
Replace the front spring assembly onto the clamp, replace the 
clamp washers, and screw on the clamp nuts.
5.
Replace the Glastic frame and screw in the mounting bolts. 
Torque to 50 lb-in.
6.
Secure the U-shape output busbar, replacing the two bolts and 
torquing them to 25 lb-ft.
7.
Torque the spring assembly to 10,000 lb-ft (10 on spring indica-
tor).
!
ATTENTION: The heatpipe assembly weighs 
about 75 lbs. Take the proper precautions (adhere 
to your company material handling procedures) 
when lifting the assembly to prevent personal injury 
and damage to the equipment.
Red
White
1395 Drives
SD3100 Drives
!
ATTENTION: Ensure that the SCRs are installed with 
the proper polarity. Improper installation will result in 
damage to the power bridge and may damage other 
externally connected equipment.