Rockwell Automation 5100 Background Suppression Control Type 42MBS User Manual

Rockwell Automation Equipment

Advertising
background image

INSTALLATION INSTRUCTIONS

PHOTOSWITCH BACKGROUND SUPPRESSION

CONTROL TYPE 42MBS SERIES 5100

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION, REFER TO PUBLICATION P



A 8921

SPECIFICATIONS

Voltage Supply

Type



42MTB 5000



102 132VAC, 50/60Hz

. . . . . . . . . . . . .

Type



42MTB 5001



204 264VAC, 50/60Hz

. . . . . . . . . . . . .

Type



42MTB 5002



40 54VAC, 50/50Hz

. . . . . . . . . . . . . . .



40 54VDC

Type



42MTB 5003



20 30VAC, 50/60Hz

. . . . . . . . . . . . . . .

Type



42MTB 5004



20 30VDC

. . . . . . . . . . . . . . . . . . . . . . .

Power Consumption

2VA @ 120VAC,

. . . . . . . . . . . . . . . . . . . .

4VA @ 240VAC

1VA @ 24/48VAC

Response Time

Type 42MBS -- 5ms

. . . . . . . . . . . . . . . . . . . . . .

with EM Relay



#8 590,



#8 594

Operate 10ms additional

. . .

Release 15ms additional

with FET Relay



#8 591

1ms additional

. . . . . . . . . . . . . . . . .

with Triac Relay



#8 592

8ms additional

. . . . . . . . . . . . . . . .

with dual Source/Sink



#8 593

1ms additional

. . . . . . . . . . . .

Light/Dark Energized option

Yes

. . . . . . . . . . . . . . . . . . . . . . .

Turn on Pulse Suppression

Yes

. . . . . . . . . . . . . . . . . . . . . . . . .

Gain Margin and Alignment Indicators

Red

Output Energized

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Green

2X margin

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field of View

3

o

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suppression Point Adjustment Range

2.5

”--12”

. . . . . . . . . . . .

(6.3--30.5cm)

SUPPRESSION QUALITY SPECIFICATIONS

(Based on Operating Margin of 20)

White Background (Unit Off)

Black Target (Unit On)



2.5

” (6.35cm)



2.3

” (5.84cm)



4

” (10.1cm)



3.9

” (9.9cm)



6

” (15.2cm)



5.8

” (14.7cm)



8

” (20.3cm)



7.7

” (19.5cm)

10

” (25.4cm)



9.5

” (24.1cm)

12

” (30.5cm)

10.5

” (26.6cm)

Timing Ranges

Short

Long

Two Way Time Delay (ON & OFF Delays



0 1.5 sec.



0 15 sec.

ON Delay



0 1.5 sec.



0 15 sec.

OFF Delay



0 1.5 sec.



0 15 sec.

One Shot



0 1.5 sec



0 15 sec.

Delayed One Shot



0 1.5 sec



0 15 sec.

Transmitting LED

Infrared 880nm

. . . . . . . . . . . . . . . . . . . . . . .

Lens Material

Acrylic with protective hard coating

. . . . . . . . . .

Housing Material

High Impact, chemically resistant Valox

. . . .

Operating Environment:

NEMA 3, 4, 12, 13 and IP66 (IEC144) rated housing

Ambient Temperature

--40

F to 150

F

. . . . . . . . . . . . . . . . . . . .

--40

C to 65

C

Relative Humidity

90%

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Terminal Base

Supplied with



#6 32 nickel plated

. . . . . . . . . . .

brass pressure type terminal.

ORDERING INSTRUCTIONS

1. Order Type 42MBS Model 5100 Photohead.

2. Select output.

PART

NUMBER

TYPE

RATING



8 590 &



8 594*

(SPDT) EM--RELAY

2A, 120 VAC

1A, 240VAC

8--591



(SP NO) FET SS--RELAY

30mA CONT.



0 120VAC/DC

8--592



(SP NO) AC POWER TRIAC

SS RELAY

.75A CONT.

10A SURGE

24--240VAC



8 593*

NPN & PNP SINK/SOURCE

100mA AT 30VDC

* Use with 42MTB--5004 base only. Other output modules will not func-

tion with 5004 base.

3. Select power base.

VOLTAGE SUPPLY

TYPE AND MODEL

120VAC

42MTB- 5000

240VAC

42MTB- 5001

48VAC/DC

42MTB- 5002

24VAC

42MTB- 5003

24VDC

42MTB- 5004

4. Select optional mounting accessories.

PART NUMBER

DESCRIPTION

60- 1785

Universal Mounting Assembly 360

o

Adj.

60- 1748

Heavy--Duty Mounting Assembly



60 2014



Flexi Mount Mounting Assembly

60- 2072

Photocount Switch Totalizer

60- 2083

Photoguard Heavy Duty Protection

60- 2213

Conduit Mounting Adaptor

60- 2230

Limit Switch Type Mounting Assembly

INSTALLATION

The control must be securely mounted on a firm, stable surface

or support. A mounting which is subject to excessive vibration or

shifting may cause intermittent operation. For installation conve-

nience, Heavy Duty Mounting Assembly



#60 1748, or Universal

Mounting Assembly



#60 1785, is recommended. For excessive vi-

bration environments, use Solid State Relay outputs.

Wiring:

It is recommended that



Plug In Output devices be inserted prior

to wiring to the terminals. Also, sufficient “loop” should be provided

for wiring connections to terminals in order to facilitate insertion or

removal of the



Plug In Output device.

All external wiring should conform to the National Electrical

Code and applicable local codes. See Wiring Diagram for electrical

connections (page 2).

Advertising