Figure 1, Set up instructions, Control adjustments – Rockwell Automation 5100 Background Suppression Control Type 42MBS User Manual

Page 2: Figure 2 typical response curve, Figure 3 typical suppression curve, Figure 4

Advertising
background image

2

TYPE 42MBS SERIES 5100 CONNECTION DIAGRAMS

L2

SOLID STATE

RELAY

OUTPUT

C

NO

1

2

3

42MTB--5004 WITH #8--593 ONLY and



8 594*

TTL LOGIC

+ 5 VDC

(CURRENT SINK)

(CURRENT

SOURCE)

RELAY LOAD

20--30 VDC

NOTE: MULTIPLE CONTROLS

CAN BE CONNECTED IN “AND”

OR “OR” LOGIC BY USE OF THE

PNP OUTPUT ON TERMINALS #2

AND #3.

L1

L2

L1

EM RELAY

OUTPUT

NC

C

NO

42MTB--5000

42MTB--5001

42MTB--5002

42MTB--5003

120 VAC

240 VAC

48 VAC/DC

24 VAC

42MTB--5000

42MTB--5001

42MTB--5002

42MTB--5003

120 VAC

240 VAC

48 VAC/DC

24 VAC

+

_

_

+

*NOTE: When using



E M relay



#8 594 contact terminals

are:

1 NO 2 C 3 NC

FIGURE 1



SET UP INSTRUCTIONS

1. Loosen lock to make the sensing Range adjustment possible.

2. Adjust “Coarse” sensing range adjustment to the maximum po-

sition. (Full counterclockwise position).

3. Set the Light Energized (LT)/Dark Energized (DK) switch (#4)

to the Light Energized position.

4. With switch #1, select short 

(0 1.5 sec.) or long 

(0 15 sec.,)



“OFF Delay” (One--shot).

5. With switch #2, select short 

(0 1.5 sec) or long 

(0 15 sec.)



“ON Delay”



(One shot).

6. With switch #3, select “T



ime Delay” (TD) or



“One shot”

(O.S.) operation.

7. With the



On timing pot. set the



On time to minimum. (Full

counter clockwise).

8. With the



OFF timing pot set the



OFF time to maximum when

in



short OFF mode (Full clockwise) or, when in



long OFF

mode set the OFF time to at least 

2 3 seconds.

9. Adjust the “Coarse” sensing range adjustment to the minimum

position. (Full clockwise).

10. Position the control in its application and increase the sensing

range until the control senses the background. The Red LED in-

dicator will turn ON. The Green LED (2X margin indicator)

should turn ON indicating an operating margin of 2X or more ex-

ists.

11. With the Fine sensing range adjustment decrease the sensing

range till the Green LED turns OFF.

12. Place the target to be sensed in front of the control at the expected

sensing distance. The Red and the Green LED should come ON.

Remove the Target.

13. For Time Delay Operation observe the Red LED indicator. If

after the OFF delay has elapsed the Red LED indicator turns

OFF, the control has the correct adjustments and the settings

should be locked with the lock screw. If the Red LED does not

turn OFF, slightly reduce the sensing range with the fine sensing

range adjustment and repeat steps 12 and 13.

14. For



One Shot Operation. Replace the target in front of the

control after the one shot time has elapsed. Observe the Red

LED. If the Red LED comes ON, the settings are correct and can

be locked. If the Red LED does not come on, slightly reduce the

sensing range with the fine sensing range adjustment and repeat

steps 12 and 14.

15. If the dark (DK) operating mode is required, set switch #4 to the

DK position.

16. With the ON and OFF timing pots. adjust for the desired time

delays.

17. Tighten the lockscrew after adjusting the sensing range. A slight

increase in sensing distance may occur. Compensate by readjust-

ing range slightly less then required distance. Example. 5.875

(14.9cm) for a 6

” (15.2cm) suppression point. Repeat steps 10,

11 and 12 to verify the range after tightening the lockscrew.

CONTROL ADJUSTMENTS

CAUTION:

MOVE SENSING

RANGE ADJUST

TO ACCESS

FUNCTION

SWITCHES

CAUTION: LOOSEN

LOCK BEFORE

ADJUSTING SENSING

RANGE

COARSE

SENSING

RANGE

ADJUST

FINE

ON

TIMING

OFF

SHORT

OFF

LONG

OFF

SHORT

ON

LONG

ON

O.S.

T.D.

LT.

DK.

1

2

3

4

LT/DK

FIGURE 2

TYPICAL RESPONSE CURVE

SUPPRESSION SET FOR 8” (20.3cm)

OP

ER

AT

IN

G

M

AR

G

IN

OPERATING DISTANCE

100X

10X

.1”

(.25cm)

1000x

1X

.3”

(.76cm)

.5”

(1.27cm)

.8”

(2.03cm)

2”

(5.08cm)

4”

(10.1cm)

6”

(15.2cm)

8”

(20.3cm)

10”

(25.4cm)

12”

(30.5cm)

FIGURE 3

TYPICAL SUPPRESSION CURVE

0

2”

4”

6”

8”

10”

12”

14”

0

2”

4”

6”

8”

10”

12”

14”

(5.08cm) (10.1cm) (15.2cm) (20.3cm) (25.4cm) (30.5cm) (35.5cm)

(30.5cm)

(35.5cm)

(25.4cm)

(20.3cm)

(15.2cm)

(10.1cm)

(5.08cm)

6.1%

2.6%

DISTANCE TO BACKGROUND OBJECT

DI

ST

AN

CE

TO

SE

NS

ED

O

BJ

ECT

(O

PERA

TING
M

ARG

IN

=

16

)

(O

PE

RA

TING
M

ARG
IN

=

38)

WHITE PAPER

FIGURE 4