Publication 2706-IN020A-EN-P - January 2004

PN 41061-345-01(1)

Supersedes Publication XXXX-X.X.X - Month Year

Copyright © 2004 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

InView Display Mounting

The following instructions provide panel cutout dimensions for the InView P22R
Panel Mount Display.

The InView P22R mounts in a custom panel or enclosure. When it is properly
installed, the faceplate provides a NEMA Type 12, 13, and 4X(indoor) rating. To
install the InView Display:

1. Cut and drill the appropriate mounting holes in the enclosure or panel.

2. Remove the six mounting nuts from the hardware bag provided with the

display.

3. Position the InView Display in the panel or enclosure mounting hole.

4. Install nuts and alternately tighten the nuts to a torque of 0.904 Nm (8 in-lb).

Panel Cutout Dimensions

Cutout 345.9 (13.62)

Cutout

173.0 (6.81)

98.4

(3.88)

352.3 (13.87)

Cutout

88.9

(3.50)

176.3 (6.95)

4.8 (0.19)

4.8 (0.19)

6.4 (0.25)

Diameter
Hole

6 places

2706-P22R Display

All dimensions are in millibeters (inches)

Advertising