Continuous Flexible Power Cables Installation Instructions 5

Publication 2090-IN025A-EN-P — October 2009

Never bend a cable tighter than the specified bend radius. Refer to

Specifications

for value.

3. When installing a continuous flexible cable observe these restrictions on the

flex zone and installation area:

• The flex zone is the area in which the cable can repeatedly flex up to its

specified bend radius.

• The installation areas require rigid mounting to prevent the cable from

flexing where it connects to other components.

4. Identify each connection on a cable by attaching a label around the outer

insulation of each wire adjacent to the drive connection.

5. Remove the O-ring on the motor connector when using a power cable with

a SpeedTec power plug.

The type of plug on the cable determines whether an O-ring is required on
the receptacle.

IMPORTANT

The O-ring dampens the effects of vibration at the cable-to-motor connection. This
creates a more secure connection for a cable with a threaded plug.

SpeedTec Plug

Threaded Plug

Remove O-ring when mating with a
SpeedTec plug.

Install O-ring when mating with a
threaded plug.

O-ring in groove.

If an O-ring is installed, a SpeedTec plug will not engage with the receptacle.