Install cables – Rockwell Automation 2090-CPxxx Standard Power Cables with SpeedTec DIN Connector Type 923 User Manual

Page 4

Advertising
background image

4 Standard Power Cables with SpeedTec DIN Connector Type 923

Publication 2090-IN022A-EN-P - September 2010

Install Cables

Follow these steps when installing a cable.

1.

Identify the recommended installation areas and the correct offset from features before
beginning any cable bend. Features include these areas on the cable:

Connectors

Transitions from exposed wire to insulation (for example, flying leads)

Exposed cable ground shields

The offset from these features should be greater than or equal to (>1x) the cable
diameter.

ATTENTION: The examples in this publication show all the available
connections, some of which may not be appropriate for your specific
installation. Refer to your drive installation or user manual for recommended
wire trim lengths, and wiring examples appropriate to your drive and motor
application.

Do not connect unused wires. Unused wires may be trimmed and finished as
necessary to prevent accidental contact with other wires or wire shields, or with
a ground connection.

IMPORTANT

Motors equipped with SpeedTec-ready DIN connectors are fully compatible with
threaded (M4) cable plugs. SpeedTec-ready DIN motor connectors are also
compatible with SpeedTec (M7/E7) cable plugs when the o-ring on the motor
connector is removed.

Motors equipped with threaded DIN (M4) connectors are compatible only with
threaded (M4) cable plugs.

U

PE

V

W

MBRK+

MBRK-

Limited

Bend Zone

Installation

Area

Installation

Area

Label

(6 Places)

Exposed

Shields

Shrink Wrap

Refer to

Specifications

for recommended

Installation Area and Bend Zone values.