PowerFlex 700 Parameter Record

Machine #
Date programmed
Drive Serial #

Par

Parameter Name

Minimum Value

Maximum Value

Factory Default

Programmed Value

1

Output Freq

- [Maximum Freq]

+ [Maximum Freq]

Read Only

2

Commanded Freq

- [Maximum Speed]

+ [Maximum Speed]

Read Only

3

Output Current

0.0 Amps

Drive Rated Amps x 2

Read Only

4

Torque Current

Drive Rating x -2

Drive Rating x +2

Read Only

5

Flux Current

Drive Rating x -2

Drive Rating x +2

Read Only

6

Output Voltage

0.0 VAC

Drive Rated Volts

Read Only

7

Output Power

0.0 kW

Drive Rated kW x 2

Read Only

8

Output Powr Fctr

0.00

1.00

Read Only

9

Elapsed MWh

0.0 MWh

429496729.5 MWh

Read Only

10

Elapsed Run Time

0.0 Hrs

429496729.5 Hrs

Read Only

11

MOP Frequency

- [Maximum Frequency]

+ [Maximum Frequency]

Read Only

12

DC Bus Voltage

Based on Drive Rating

Based on Drive Rating

Read Only

13

DC Bus Memory

Based on Drive Rating

Based on Drive Rating

Read Only

16

Analog In1 Value

0.000 mA

-10.000V

20.000 mA

+10.000V

Read Only

17

Analog In2 Value

0.000 mA

-10.000V

20.000 mA

+10.000V

Read Only

26

Rated kW

0.37 kW

15.0 kW

Read Only

27

Rated Volts

Based on Drive Rating

Based on Drive Rating

Read Only

28

Rated Amps

1.1 Amps

32.2 Amps

Read Only

29

Control SW Ver

0.000

65.256

Read Only

40

Motor Type

Induction

Induction

Synchr Reluc

Synchr PM

41

Motor NP Volts

0.0 VAC

[Rated Volts]

Based on Drive Rating

42

Motor NP FLA

0.0 Amps

[Rated Amps] x 2

Based on Drive Rating

43

Motor NP Hertz

5.0 Hz

400.0 Hz

Based on Drive Cat. No.

44

Motor NP RPM

60 RPM

24000 RPM

1750 RPM

45

Motor NP Power

0.0

100.0

Based on Drive Rating

46

Mtr NP Pwr Units

Horsepower

Based on Drive Rating

kiloWatts

47

Motor OL Hertz

0.0 Hz

Motor NP Hz

Motor NP Hz/3

48

Motor OL Factor

0.20

2.00

1.00

53

Torque Perf Mode

Sensrls Vect

Sensris Vect

SV Economize

Custom V/Hz

Fan/Pmp V/Hz

54

Maximum Voltage

Rated Volts x 0.25

Rated Volts x 1.0

Drive Rated Volts

55

Maximum Freq

5.0 Hz

400.0 Hz

110.0 or 130.0 Hz

56

Compensation

Reflect Wave

1

Enable Jerk

1

57

Flux Up Mode

Manual

Manual

Automatic

58

Flux Up Time

0.00 secs

5.00 secs

0.00 secs

61

Autotune

Ready

Calculate

Static Tune

Rotate Tune

Calculate

62

IR Voltage Drop

0.0 VAC

[Motor NP Volts] x 0.25

Based on Drive Rating

63

Flux Current Ref

0.00 Amps

[Motor NP FLA]

Based on Drive Rating

69

Start/Acc Boost

0.0 VAC

[Motor NP Volts] x 0.25

Based on Drive Rating

70

Run Boost

0.0 VAC

[Motor NP Volts] x 0.25

Based on Drive Rating

71

Break Voltage

0.0 VAC

[Motor NP Volts]

[Motor NP Volts] x 0.25

72

Break Frequency

0.0 Hz

[Motor NP Freq]

[Motor NP Freq] x 0.25

80

Speed Mode

Open Loop

Open Loop

Slip Comp

Process PI

81

Minimum Speed

0.0 Hz

[Maximum Speed]

0.0 Hz

82

Maximum Speed

5.0 Hz

400.0 Hz

50.0 or 60.0 Hz (Dependent

on voltage class)

83

Overspeed Limit

0.0 Hz

20.0 Hz

10.0 Hz

84

Skip Frequency 1

- [Maximum Speed]

+ [Maximum Speed]

0.0 Hz

85

Skip Frequency 2

- [Maximum Speed]

+ [Maximum Speed]

0.0 Hz

86

Skip Frequency 3

- [Maximum Speed]

+ [Maximum Speed]

0.0 Hz

87

Skip Freq Band

0.0 Hz

30.0 Hz

0.0 Hz