Installation

This chapter describes how to install a 1442 Series Eddy Current Probe System.

ATTENTION: Always ground the system. Never apply power until all
wiring work and connection work has been completed. If this is not
followed, there is a possibility of electrocution.

Installation work, wiring, and connections must be performed by a person
with knowledge in instrumentation.

ATTENTION: Be sure to adhere to the following guidelines:

• Before touching this unit, be sure to touch a metal section near by to

discharge any static electricity. The device can be damaged if exposed to
static electricity from a person’s body.

• Before applying power, make sure that all wiring is properly connected.

There is a possibility of damage to the unit and fire if improperly
connected.

• Install this unit away from motors and relays.

• Install the input/output signal cables away from power system and

control system cables. Noise occurring from the motor or relay can
adversely affect the measurement value. We recommend using separate
wiring ducts.

• Do not pull or bend the sensor cables and extension cables with

excessive force. The conductor in the cable can get cut off.

• The allowable tension of the sensor cables and extension cables is

98.1 N•m (10 kgf•m). The allowable bend radius is as follows:

– Without armored cable: 30 mm (1.18 in.)

– With armored cable:

50 mm (1.97 in.)

• After completing the installation, make sure all connections are correct

and tight before powering the system.

TIP

Refer to Appendix A on

page 51

for recommended cable wiring, and

installation methods.