Rockwell Automation FlexPak Plus Reversing Contactor Kit 14C400, 401, 402 User Manual
Accessory reversing contactor kit

1
INSTRUCTION MANUAL DĆ3959Ć1
ACCESSORY
REVERSING CONTACTOR KIT
MODEL NUMBERS 14C400, 14C401, 14C402
ASSEMBLY DRAWINGS 705385Ć75
The equipment described below should be installed only by qualified electrical maintenance personnel
familiar with the construction and operation of the equipment and the hazards involved.
DESCRIPTION
The standard threeĆphase FlexPak Plus/MinPak Plus
controller offersunidirectional control. See figure 1. With
an optional reversing contactor kit mounted on the
auxiliary panel, bidirectional operation (both forward
and reverse) is possible. See figure 2. Motor direction is
manually selected.
Figure 1 - ThreeĆPhase MinPak Plus/FlexPak Plus
Reversing Kit
CAUTION
The FlexPak Plus
/MinPak Pluscontrollerswere
designed for motoring operation only. In reversing
applications the drive must be assured to come to a
rest before the reversing contactor is pulled in. If not, the
possibility of transient regenerative currents can occur
with the result being significant damage to the controller.
Figure 2 - Reversing Kit Installed On Auxiliary
Panel
The thick black bar shown on the rightĆhand margin of this page will be used throughout this instruction manual to signify
new or revised text or figures.