Replacing the Power Supply Assembly
4
5
2
2
Insulation
Sheet
(supplied with drive)
Metal
Standoff
2
3
3
4
5
Install (or re-use) the 3 plastic spacers (P/N 179773).
1
1
Verify that the metal standoff is fastened securely to the Power Interface assembly.
(supplied
with drive)
Place the insulation sheet onto the plastic spacers over the Power Interface
Carefully align and press the Power Supply assembly (P/N 193087-A02) onto the
assembly. Verify that the warning label is at the bottom of the sheet when installed.
Fasten (and ground) the Power Supply assembly to the Power Interface assembly
using the PHMS screw (P/N 419062-1PGF). Torque = 1.4 to 1.8 N-m (13 to 16 in/lb).
Torque = 1.4 to 1.8 N-m (13 to 16 in/lb).
Power Interface
Assembly
Power Supply
Assembly
plastic spacers until fastened.