Rockwell Automation LiquiFlo 2.0 Switch Mode Power Supply Replacement User Manual

Page 2

Advertising
background image

Publication D2-3512-1 - June 2004

2004 Rockwell Automation. All rights reserved.

Replacing the Power Supply Assembly

4

5

2

2

Insulation
Sheet
(supplied with drive)

Metal
Standoff

2

3

3

4

5

Install (or re-use) the 3 plastic spacers (P/N 179773).

1

1

Verify that the metal standoff is fastened securely to the Power Interface assembly.

(supplied
with drive)

Place the insulation sheet onto the plastic spacers over the Power Interface

Carefully align and press the Power Supply assembly (P/N 193087-A02) onto the

assembly. Verify that the warning label is at the bottom of the sheet when installed.

Fasten (and ground) the Power Supply assembly to the Power Interface assembly
using the PHMS screw (P/N 419062-1PGF). Torque = 1.4 to 1.8 N-m (13 to 16 in/lb).

Torque = 1.4 to 1.8 N-m (13 to 16 in/lb).

Power Interface

Assembly

Power Supply
Assembly

plastic spacers until fastened.