TL-Series Servo Motor Installation Instructions

Publication TL-IN001C-EN-P — March 2005

Recommendations on Installing TL-Series Motors

Observe the following recommendations when installing the motor.

1. Allow sufficient clearance around motor to keep it from exceeding its maximum

operating temperature range. Refer to Receiving and Storage on page 2 for the
operating range. Do not install the motor in an area with restricted airflow. Keep
other heat producing devices away from the motor.

To obtain the specified motor thermal rating, mount the motor on a surface
with heat dissipation equivalent to an aluminum heatsink of the following
dimensions:

!

ATTENTION

TL-Series motors are not for direct connection to an AC power
line.

Servo motors are designed for connection to a servo drive that
controls the application of AC power. Failure to observe these
safety procedures could result in damage to the motor and
equipment.

Motor Frame Size

Heatsink Dimensions

millimeters inches

TL-A1xx

203.2 x 203.2 x 6.35

8 x 8 x 0.25

TL-A2xx

254.0 x 254.0 x 6.35

10 x 10 x 0.25

TL-A25xx, TL-3xx, and TL-A4xx

304.8 x 304.8 x 12.7

12 x 12 x 0.50

!

ATTENTION

Outer surfaces of motor can reach high temperatures, 125° C
(257° F) during motor operation.

Take precautions to prevent accidental contact with hot
surfaces. Locate the motor and route cable connections to avoid
contact with hot surfaces.

Failure to observe these safety procedures could result in
personal injury or damage to equipment.