Calibration

7. Set the voltage input signal to Vimax.
8. Calculate the test point voltage, Vtp:

(Vimax) (m)

Vtp =

2

where

Vomax – Vomin

m =

Vimax – Vimin

9. Adjust the SIGNAL INPUT ADJ trimmer potentiometer (P501) so that the

voltage from COM to TP (terminal 7 to 10) is Vtp.

10. Adjust the MAX OUT trimmer potentiometer (P502) so that the voltage output

signal is Vomax.

11. Repeat steps 4, 5, 6, 7, 9, and 10. Use the same voltage values that you

previously calculated.