3-6
GV3000/SE 230 VAC 1-20 HP Drive, Hardware Reference Version 6.04
GV3000/SE
Drive
GV3000/SE
Drive
GV3000/SE
Drive
GV3000/SE
Drive
Motor
Motor
Motor
Motor
Motor
Motor
Motor
38 m (125')
38 m (125')
15 m (50')
61 m (200')
8 m (25')
61 m (200')
8 m (25')
76 m (250')
All examples represent 76 m (250') of motor lead length.
Figure 3.3 – How to Measure Motor Lead Lengths
Table 3.7 - Motor Lead Lengths
GV3000/SE
HP Rating
Maximum Lead Length in Feet with
230 VAC Motor
Carrier Frequency
Filter Type
2 kHz
4 kHZ
8 kHZ
1 to 2
3 to 5
7.5 to 10
15 to 20
1 to 2
3 to 5
7.5 to 10
15 to 20
500
500
750
800
1000
1000
1000
1000
500
500
500
500
1000
1000
1000
1000
500
500
500
500
1000
1000
1000
1000
None
A 5% MTE
reactor/filter at the
drive.
Note that the lead lengths listed are valid with Reliance Electric inverter duty motors.
Table 3.8 - Reactors
GV3000/SE
HP Rating
GV3000/SE
HP Rating
240 Volt
5% MTE Reactor
240 Volt
5% MTE Reactor
1
2
3
5
7.5
10
15
20
RL-00402
RL-00802
RL-01202
RL-01802
RL-02502
RL-03502
RL-04502
RL-05502
These part numbers are for a reactor with a capacitor filter.
MTE standard reactors can be used on GV3000/SE drives with carrier frequency settings up to 8 kHZ.
All reactors listed are UL-recognized (UL-506 File #E53094) and CSA certified (CSA File #LR29753).