Rockwell Automation Isomag 4 Universal Guard Safety Switch User Manual

Isomag 4

Advertising
background image

Actuator

Switch

UNIVERSAL
GUARD
SAFETY
SWITCH

Follow steps 1 to 7 for correct installation.

INSTALLATION INSTRUCTIONS

Isomag 4

Security Key

Cover
Retaining
Screws

Cover

Coduit

Entries

Isomag

Insulating

Barrier

Operating

Cam

Safety Contacts

Internal
Contact
Cover

Aux Contacts

Hinged Guards

Sliding Guards

Lift-Off Guards

The cover of the Isomag switch
hinges down to allow access to
the fixing holes. Unscrew the 2
cover retaining screws using the security key supplied and
swing down the cover. The internal plastic cover protects the
electrical contacts and the ISOMAG Insulating Barrier.
The ISOMAG 4 can be fitted in any position on hinged,
sliding or lift-off guards.

The switch will accommodate inaccuracies in the guard or door but it should not
be used as a guide. When correctly installed the bottom of the actuator tongue
should clear the entry hole by 1mm. When the guard is closed there should
be a gap of 3 to 6mm between the actuator and switch faces.

On hinged guards the
minimum radius from the
hinge point to the actuator
tongue centre
should be as
shown.

Min radius

370mm

Min radius
170mm

3 to
6mm

1mm

40

Switch

Actuator

M5

60.5

19.5

Hinge down the cover to gain access to the
mounting holes. Mount the switch on the
stationary section of the guard using 2 x
M5 fixings. Use mounting brackets if
necessary.

Mount the actuator on the moving guard
section with the actuator tongue centrally
opposite the switch entry hole. Use the
two security screws provided. The
elongated holes allow adjustment before
fully tightening the screws.

The guard door
must be fitted
with a stop to
ensure a gap of
3 to 6mm. The
actuator MUST
NOT be allowed
to strike the
switch when the
guard door is
closed.

3mm MIN

6mm MAX

STOP

150mm

The switch cover can be hinged
down for high pressure hosing.
A gap of 150mm is required to allow
the switch lid to hinge down.

5

3

4

2

1