Dimensions, Accessories technical specifications – Rockwell Automation Isomag 4 Universal Guard Safety Switch User Manual

Page 2

Advertising
background image

6

Remove the internal cover and connect the
contact terminals as shown. Use the most
convenient of the 3 knock out conduit entry
points.

7

After installation check all of
the interlocked guard doors
to ensure that the machine is
isolated and stopped before
the guard has been opened
a sufficient distance to allow
access to the hazardous
area.

DIMENSIONS

5.25

30

5

81

60.5

5.25

M4

10

18

5.25

18

2

53

121.3

64.3

M5

35.05

13.3

11.5

15

BS 20mm

CONDUIT

ENTRY

20

20

58

38

Safety contacts:

Safety contact gap:

Auxiliary contacts:

Case:

Switch interior:

Protection:

Mounting:

Fixing:

Cover screws:

Cleaning:

Operating temperature:

Operating life:

Conduit entries:

Actuator:

Fixing:

Double positive break, N/O, AC11 500V 1A

250V 2A
100V 5A

DC11 240V 0.5A

> 2 x 2.6mm.
Double positive break, N/C, AC11 500V 1A

250V 2A
100V 5A

DC11 240V 0.5A

Heavy duty die cast alloy, epoxy coated, colour red.
Glass reinforced nylon, self extinguishing.
IP66.
Any position.
2 x M5.
Resistorx anti-tamper.
May be steam cleaned or high pressure hosed.
-35

°

C to +80

°

C.

> 10 x 10

6

3 x BS20mm
Pressed steel, chrome plated. Magnet housing
moulded ABS.
2 x M4 Resistorx anti-tamper (supplied).

The Isomag 4 is available with alternative PG11 conduit threads.
Spare Actuator
Stuffing Gland - BS20mm
Stuffing Gland - PG11
Conduit Beacon - Indicator light (supplied without bulb) fits in spare
conduit entry hole
Bulb for above - 24V, 110V, 240V (specify vo;tage).
Security Key
Screwdriver (inc. security key)

ACCESSORIES

TECHNICAL SPECIFICATIONS

Drg no. 10506/0

11

12

22

24

SAFETY
CIRCUIT

AUX

CIRCUIT

R

Advertising