AC Digital Input Module (T7404)
1 2
Industrial Control Services
Specifications
Safetybus Power
1.15 load units
Number of Inputs
16 circuits divided into two
groups of eight
Voltage Range
90 to 130 VAC
Frequency Range
47 to 63 Hz
Turn-On Voltage
89 VAC, minimum
Turn-Off Voltage
30 VAC, maximum
Input Current
3.9 mA, typical
Turn-On Delay
minimum
maximum
3.5 msec
20 msec
Turn-Off Delay
minimum
maximum
3.5 msec
15 msec
Over Voltage Protection
continuous:
burst:
160 VAC
260 VAC, for 5 sec
Heat Dissipation
14 Watts, 48 BTUs/hour
Fusing
None, fuse external if
required
Isolation
2500 volts minimum (field
wiring to control logic)
2500 volts minimum (input
group 1-8 to input group
9-16)
Operating Temperature
0
°
to 60
°
C
(32
°
to 140
°
F)
Storage Temperature
-40
°
to 85
°
C
(-40
°
to 185
°
F)
Operating Humidity
0 to 95% relative humidity,
non-condensing
Vibration
10 to 55 Hz:
±0.15mm