5-2

Parallel Gate Amplifier

5.2

Installing the PGA Rack

The rack is designed to be panel-mounted using M6 or 1/4"-20 screws. The holes in
the top flange have a keyhole shape and the lower holes are U-shaped to facilitate
mounting. Refer to figure 5.1 (four-slot rack) or figure 5.2 (eight-slot rack) for mounting
dimensions.

Use the following guidelines when installing the PGA rack:

Ensure that there is enough space for the rack, wiring, terminal strips, and other
devices that must be mounted near the rack.

Allow a large enough clearance around the rack to provide access for inspection,
maintenance, and module replacement.

Allow 50 mm (2 in) of clearance above and below the rack for ventilation.

Do not mount heat-generating equipment underneath the rack.

Mount the rack in a vertical position only.

The cabling distance between the PGA rack and the Power Module must not
exceed 18.3 m (60 ft).

Rack surrounding air temperature must be between 0

°

C (32

°

F) and 60

°

C

(140

°

F).

Relative humidity must be between 5 and 95% (non-condensing).

Surrounding air must be clean and dry (e.g., free of flammable or combustible
vapors, chemical fumes, oil vapor, steam, excessive moisture, and dirt).