Table 6 – Matching Enclosed Transistor Kits and Enclosed Resistor Kits (460 VAC)

Transistor

Braking Kit

Model

Number

Braking

HP

DC

Amps

RMS

6% Duty Cycle

1

1.

Maximum on-time is 60 seconds

20% Duty Cycle

1

Enclosure

Type

Resistor

Braking Kit

Model Number

Peak

Braking

Watts

Continuous

Braking

Watts

Resistor Braking

Kit Model

Number

Peak

Braking

Watts

Continuous

Braking

Watts

M3575TH15

1

1

M3575RH1M

746

50

M3575RH1MF

746

150

M4

2

2

M3575RH2M

1492

100

M3575RH2MF

1492

300

M4

3

3

M3575RH3M

2238

150

M3575RH3MF

2238

450

M4

4

4

M3575RH4M

2984

200

M3575RH4MF

2984

600

M7

5

5

M3575RH5B

4000

250

M3575RH5BF

4000

800

B4

6

6

M3575RH6M

4476

300

M3575RH6MF

4476

900

M7

8

8

M3575RH8B

6000

350

M3575RH8BF

6000

1200

B4

9

9

M3575RH9M

6714

400

M3575RH9MF

6714

1350

M10

11

11

M3575RH11B

8000

450

M3575RH11BF

8000

1600

B7

M3575TH30

16

16

M3575RH16B

12000

700

M3575RH16BF

12000

2400

B7

24

24

M3575RH24B

18000

1000

M3575RH24BF

18000

3600

B10

M3575TH75

50

53

M3575RH50G1F

40000

8000

G1

M3575TH125

100

106

M3575RH100G2F

80000

16000

G2

M3575TH200

150

159

M3575RH150G3F

120000

24000

G3

Advertising