Rockwell Automation M3575TL Snubber Braking Kits, AC Drives, Enclosed  User Manual

Page 2

Advertising
background image

2

Enclosed Resistor Modules, Enclosed Transistor Modules

Snubber Braking kits are available:

as an Enclosed Resistor module for use with an AC drive containing a built-in transistor switching circuit
(such as the GV3000/SE Bookshelf AC drive) or for use in conjuction with an enclosed transistor module
(M/N M3575T__)

as an Enclosed Transistor module (M/N M3575T__) for use with AC drives that do not contain a built-in
transistor switching circuit and for use with the enclosed resistor modules (M/N M3575R__)

Note that all of the Enclosed Resistor modules and Enclosed Transistor modules are rated for a maximum
on-time of 60 seconds at a specified duty cycle (see tables 1, 2, 5 and 6).

For GV3000/SE Bookshelf drives: Refer to tables 1, 2, and 3 to ensure that the Enclosed Resistor kit
matches your drive.

For AC Drives requiring both an Enclosed Resistor kit and an Enclosed Transistor kit: Refer to tables 4,
5, and 6 to ensure that the braking kits match your drive and your braking horsepower requirements.

Snubber Resistor Kits (M3575RH__, M3575RL__)

The figure below depicts the breakdown of the Snubber Resistor kit part number.

Enclosed Resistor Braking Unit Fault Output

Enclosed Resistor Braking units have one normally-closed contact (NC) rated at 1 amp @ 24 VDC or
0.5 amp @ 115 VAC that opens on an overtemperature fault condition ( 85 C or higher).

M3575R H 2 M F

Base Model Number

AC Voltage Rating
L = 230 VAC
H = 460 VAC

Horsepower Rating

Chassis Style
B = Bookshelf Style
M = Mini (Standard Enclosed Style)
G = Grid Resistors (G1, G2, G3)

Cooling Option
F = Internal Fan

Advertising