Enables/disables feature that allows the drive to reconnect to a
spinning motor at actual RPM.
Enables/disables correction options that may improve problems with
motor instability
.
Electrical = Some drive/motor combinations have inherent
instabilities which are exhibited as non-sinusodial motor currents.
This setting attempts to correct this condition.
Mechanical = Some drive/motor combinations have mechanical
resonances which can be excited by the drive current regulator. This
setting slows down the current regulator response and attempts to
correct this condition.
A096
Flying Start Enable
Range:
0 = Disabled
1 = Enabled
Default:
0 = Disabled
See also:
N/A
!
ATTENTION: When starting with this feature
enabled, the motor may temporarily run up to the
maximum speed setting before settling at the speed
setpoint. Stay clear of rotating machinery. Failure to
observe this precaution could result in bodily injury.
A097 Compensation
Range:
0 = Disabled
1 = Electrical
2 = Mechanical
3 = Both
Default:
1 = Electrical
See also:
N/A